1044E-1304 Spark Series SP-5000M-CXP2 SP-5000C-CXP2 5M Digital Progressive Scan Monochrome and Color Camera Document Version: V
SP-5000M-CXP2 / SP-5000C-CXP2 - 8 - 3. Main features New Spark Series, 1” progressive scan camera Intelligent body design for easy and f
SP-5000M-CXP2 / SP-5000C-CXP2 - 9 - 4. Locations and functions 4.1 Locations and functions Lens mount C-mount (Note *1) 10
SP-5000M-CXP2 / SP-5000C-CXP2 - 10 - 4.2 Rear panel The rear panel mounted LEDs provide the following information: POWER/TRIG Amber:
SP-5000M-CXP2 / SP-5000C-CXP2 - 11 - 5. Input and output 5.1 CoaXpress interface 5.1.1 CoaXPress interface standard The SP-5000M-CXP2 and
SP-5000M-CXP2 / SP-5000C-CXP2 - 12 - Pixel format in CoaXPress can be set to either 8-bit or 10-bit output. However, as shown in the chart below, the
SP-5000M-CXP2 / SP-5000C-CXP2 - 13 - 5.1.3 The relationship between sensor bit, pixel clock and output format. In the SP-5000-CXP2, there are th
SP-5000M-CXP2 / SP-5000C-CXP2 - 14 - 5.2 Connectors and pin assignment 5.2.1 Digital Video Output (75Ω 1.0・2.3 DIN Receptacle)
SP-5000M-CXP2 / SP-5000C-CXP2 - 15 - Table – 5 Hirose 10P pin assignment (Standard) No I/O Name Note 1 O DRIVE IRIS+ Motorized Lens 2
SP-5000M-CXP2 / SP-5000C-CXP2 - 16 - 5.3.1 Line Selector In the Line Selector, the following input and output signals can be assigned.
SP-5000M-CXP2 / SP-5000C-CXP2 - 17 - 5.3.6 Line Format Controls the format of the line item selected in Line Selector.
SP-5000M-CXP2 / SP-5000C-CXP2 - 2 - Notice The material contained in this manual consists of information that is proprietary to JAI Ltd., Japan and
SP-5000M-CXP2 / SP-5000C-CXP2 - 18 - 5.3.7.2 IN and OUT matrix table The following table shows the input and output matrix table. Table – 10
SP-5000M-CXP2 / SP-5000C-CXP2 - 19 - 5.3.8 Associated GenIcam register GenICam Name Access Values Category Line Selector R/W Line1 - TTL Out 1
SP-5000M-CXP2 / SP-5000C-CXP2 - 20 - Table - 11 Pulse Generator default settings 5.4.1 Clock Pre-scaler Clock pre-scaler (Divide Value
SP-5000M-CXP2 / SP-5000C-CXP2 - 21 - 5.4.3 Pulse Generator Length Set the counter up value (number of clocks, refer to Table 14) for the se
SP-5000M-CXP2 / SP-5000C-CXP2 - 22 - Fig.8 Counter clear in Async mode
SP-5000M-CXP2 / SP-5000C-CXP2 - 23 - 5.4.9 Pulse Generator Clear Source The following clear source can be selected as the pulse generator clear
SP-5000M-CXP2 / SP-5000C-CXP2 - 24 - 5.4.10 Pulse Generator Inverter Clear Source Signal can be have polarity inverted. 5.4.11 Pulse Gene
SP-5000M-CXP2 / SP-5000C-CXP2 - 25 - 5.4.12 Associated GenICam register GenICam Name Access Values Category Pre-scaler R/W 1 to 4096 Pulse Gene
SP-5000M-CXP2 / SP-5000C-CXP2 - 26 - 6. Sensor layout, output format and timing 6.1 Sensor layout CMOS sensors used in the SP-5000M-CXP
SP-5000M-CXP2 / SP-5000C-CXP2 - 27 - 6.2. Camera output format The following table shows the relation between camera output and sensor readou
SP-5000M-CXP2Supplement The following statement is related to the regulation on “ Measures for the Administration of the control of Pollution by Elec
SP-5000M-CXP2 / SP-5000C-CXP2 - 28 - 6.3 Output timing 6.3.1 Horizontal timing Output format: 1X – 1Y Sensor Pixel Format: 8-bit 1 Cl
SP-5000M-CXP2 / SP-5000C-CXP2 - 29 - 6.3.2 Vertical timing Output format: 1X – 1Y, CXP-6_2 Sensor Pixel Format: 8-bit Trigger Mode: N, Exp
SP-5000M-CXP2 / SP-5000C-CXP2 - 30 - 6.3.3 ROI (Region Of Interest) setting In the SP-5000-CXP2, a subset of the image can be output by setting
SP-5000M-CXP2 / SP-5000C-CXP2 - 31 - 7. Operating modes 7.1. Acquisition control (change the frame rate) 7.1.1 Acquisition frame r
SP-5000M-CXP2 / SP-5000C-CXP2 - 32 - Normal TREADOUT (µs) = TROW * (HEIGHT + K + EXR) + EXC / FSYS + TWAIT + TEXP_F Frame rate(fps) = 1/Roun
SP-5000M-CXP2 / SP-5000C-CXP2 - 33 - Associated GenICam register GenICam Name Access Values Category Acquisition Frame Rate R/W 0.125 to 211 Acquisit
SP-5000M-CXP2 / SP-5000C-CXP2 - 34 - Table 38. Associated GenICam register information GenICam Name Access Values Category Exposure Mode R/W Off T
SP-5000M-CXP2 / SP-5000C-CXP2 - 35 - Associated GenICam register GenICam Name Access Values Category Exposure Auto R/W Off Continuous Once Acquisitio
SP-5000M-CXP2 / SP-5000C-CXP2 - 36 - 7.3.4 Associated GenICam register GenICam Name Access Values Category Trigger Selector R/W Acquisition S
SP-5000M-CXP2 / SP-5000C-CXP2 - 37 - 7.5. Timed mode This mode allows a single image frame to be captured with a preset exposure time by using
SP-5000C-CXP2Supplement The following statement is related to the regulation on “ Measures for the Administration of the control of Pollution by Elec
SP-5000M-CXP2 / SP-5000C-CXP2 - 38 - 7.6. Trigger width mode In this mode, the exposure time is equal to the trigger pulse width. Accordingly
SP-5000M-CXP2 / SP-5000C-CXP2 - 39 - 7.6.2 If the overlap setting is “Readout” Fig.23 Readout Note: In this mode, Exposure Active signal i
SP-5000M-CXP2 / SP-5000C-CXP2 - 40 - 7.7. RCT mode Until the trigger is input, the camera operates continuously and the video signal for the
SP-5000M-CXP2 / SP-5000C-CXP2 - 41 - 7.8. PIV (Particle Image Velocimetry) The Particle Image Velocimetry mode can be used in applications wher
SP-5000M-CXP2 / SP-5000C-CXP2 - 42 - 7.9. Sequence Mode This mode allows the user to define a preset sequence of up to 10 images, each with its ow
SP-5000M-CXP2 / SP-5000C-CXP2 - 43 - 7.9.3 Sequence ROI setting parameters 7.9.3.1 Sequence index table (Default) The following table shows
SP-5000M-CXP2 / SP-5000C-CXP2 - 44 - (6) Sequence ROI Gain Selector In Sequence ROI Gain Selector, the gain settings for each index are available. SP
SP-5000M-CXP2 / SP-5000C-CXP2 - 45 - 7.9.4 Associated GenICam register GenICam Name Access Values Category Video Send Mode Selector R/W Norm
SP-5000M-CXP2 / SP-5000C-CXP2 - 46 - 7.10 Multi ROI function This function divides one frame image into a maximum of 8 images vertically and reads
SP-5000M-CXP2 / SP-5000C-CXP2 - 47 - Fig. 28 Multi ROI settings and output image V-Binni
SP-5000M-CXP2 / SP-5000C-CXP2 - 3 - - Contents - Introduction ...
SP-5000M-CXP2 / SP-5000C-CXP2 - 48 - 7.10.2 Associated GenICam register GenICam Name Access Values Category Video Send Mode Selector R/W Normal T
SP-5000M-CXP2 / SP-5000C-CXP2 - 49 - 8. Other functions 8.1 Black level control This function adjusts the setup level. The adjusting level
SP-5000M-CXP2 / SP-5000C-CXP2 - 50 - Note2: If Analog Base Gain is set at 0dB and Digital Gain is used at high gain setting, the vi
SP-5000M-CXP2 / SP-5000C-CXP2 - 51 - OFF: Adjust manually. Once: Operate only one time when this command is set Continuous: Operate the
SP-5000M-CXP2 / SP-5000C-CXP2 - 52 - Balance White Channel Area Low Middle Left R/W Off On JAI-Custom Balance White Channel Area Low Left R/W O
SP-5000M-CXP2 / SP-5000C-CXP2 - 53 - 8.3.2 LUT Index This represents the “starting” or “input” pixel value to be modified by the Lookup Table.
SP-5000M-CXP2 / SP-5000C-CXP2 - 54 - 8.4. Gamma This command is used to set gamma between gamma 0.45 and gamma 1.0 (OFF) in 16 steps. The gamma
SP-5000M-CXP2 / SP-5000C-CXP2 - 55 - Before adjustment After adjustment Fig.34 Color sha
SP-5000M-CXP2 / SP-5000C-CXP2 - 56 - If several consecutive pixels are defective in the horizontal direction, 3 pixels for monochrome and
SP-5000M-CXP2 / SP-5000C-CXP2 - 57 - 8.8 Lens control The SP-5000M-CXP2 and SP-5000C-CXP2 can be used with 4 different types of auto iris lenses,
SP-5000M-CXP2 / SP-5000C-CXP2 - 4 - 6.3 Output timing ... -
SP-5000M-CXP2 / SP-5000C-CXP2 - 58 - 8.8.2.2 Step max. Iris control step depends on lens. The setting value uses the value
SP-5000M-CXP2 / SP-5000C-CXP2 - 59 - 8.8.4 Associated GenICam register GenICam Name Access Values Category Lens Select R/W None PIris Lens Moto
SP-5000M-CXP2 / SP-5000C-CXP2 - 60 - 8.9 ALC In the SP-5000M-CXP2 and SP-5000C-CXP2, auto gain, auto shutter and auto iris functions can be combine
SP-5000M-CXP2 / SP-5000C-CXP2 - 61 - Exposure Auto Min R/W 100 to 999999 JAI-Custom Gain Auto Max R/W 100 to 1600 JAI-Custom Gain Auto Min R/W 100 to
SP-5000M-CXP2 / SP-5000C-CXP2 - 62 - Notes: 1. If the exposure mode is OFF and the HDR mode is set to ON, the exposure mode is auto
SP-5000M-CXP2 / SP-5000C-CXP2 - 63 - 9. Camera setting 9.1 Camera Control Tool In the SP-5000M-CXP2 and SP-5000C-CXP2, control of all camer
SP-5000M-CXP2 / SP-5000C-CXP2 - 64 - 10. External appearance and dimensions Dimensions tolerance: ± 0.3mm Unit: mm Fig. 40 Outside
SP-5000M-CXP2 / SP-5000C-CXP2 - 65 - 11. Specifications 11.1 Spectral response 80.0070.0060.0050.0040.0030.0020.0010.00 0.00400 500 60
SP-5000M-CXP2 / SP-5000C-CXP2 - 66 - 11.2 Specifications table Specifications SP-5000M-CXP2 SP-5000C-CXP2 Scanning system Progressive scan,
SP-5000M-CXP2 / SP-5000C-CXP2 - 67 - Trigger mode OFF, Continuous, Timed (EPS), Timed (PIV), Trigger Width, Timed (RCT)(w/ALC) Trigger option Trigger
SP-5000M-CXP2 / SP-5000C-CXP2 - 5 - 8.2.6 Associated GenICam register ...- 51 - 8.3
SP-5000M-CXP2 / SP-5000C-CXP2 - 68 - Storage Temp. / Humidity -45C to +70C/20% to 80 % (no-condensing) Regulation CE (EN61000-6-2 and EN61000-6-3),
SP-5000M-CXP2 / SP-5000C-CXP2 - 69 - Appendix 1. Precautions Personnel not trained in dealing with similar electronic devices should not service t
SP-5000M-CXP2 / SP-5000C-CXP2 - 70 - 4. Caution when mounting the camera When you mount the camera on your system, please make sure to use screws
SP-5000M-CXP2 / SP-5000C-CXP2 - 71 - Manual change history Date Revision Changes Nov. 2013 1.0 New release Nov. 2013 1.1 Correct figures for HBlankin
SP-5000M-CXP2 / SP-5000C-CXP2 - 72 - User's Record Camera type: SP-5000M-CXP2 / SP-5000C-CXP2 Revision: …………….. Serial No. …………….
SP-5000M-CXP2 / SP-5000C-CXP2 - 6 - Introduction EMVA 1288 With regard to signal to noise ratio in this manual, specifications measured by EMVA 12
SP-5000M-CXP2 / SP-5000C-CXP2 - 7 - 1. General The SP-5000M-CXP2 and SP-5000C-CXP2 are among the first new Spark Series cameras to be i
Komentáře k této Příručce